- US Market Split‑Phase Hybrid Solar Inverter, 6200VA/6200W for American residential solar storage
- Pure sine wave 120V/240V split‑phase AC output, perfect for North America home power backup
- Works with 51.2V lithium‑ion battery & lead‑acid battery, max 100A adjustable AC charge current
- Supports up to 4HP heavy motor loads, ideal for off‑grid solar energy storage systems
- Full protection: overload, short‑circuit, AC reverse protection for safe home emergency power supply
- Auto 50/60Hz frequency detection, high‑efficiency conversion for whole‑house solar backup solution
Us Version 6.2KW Split Phase Solar Inverter 120V/240V Hybrid Off Grid Pure Sine Wave Solar Power Inverter
Product Introduction
Product Features
-
120/240V pure sine wave split‑phase output
-
51.2V battery input with max 100A AC charging current
-
6200W rated power & 12000VA peak power, support 4HP motor load
-
complete overload & short‑circuit full protection
Detailed description
Key Highlights of 6.2KW US Standard Hybrid Inverter
1 6.2kw US standard split phase hybrid solar inverter 120V 240V dual output pure sine wave 48V dc compatible lithium lead acid gel agm battery built in high current mppt charge controller max pv input wide pv voltage range 60hz default for north america market stable power supply for whole household heavy loads dryer pump air conditioner refrigerator
2 high conversion efficiency up to 99 percent multi power source automatic switching solar battery grid generator four working modes solar priority utility priority battery only hybrid charging ultra fast ups transfer no power outage during grid loss support multiple units parallel expand total power capacity for large residence and light commercial projects
3 intelligent operation and remote monitoring lcd touch screen real time energy data display adjustable battery charging parameters built in wifi module mobile app remote check charging discharging status fault alarm one click parameter setting rs485 communication port support auto generator start trigger low battery voltage automatic generator activation
4 complete multi layer safety protection overvoltage overload short circuit overtemperature reverse pv reverse battery reverse grid connection protection clear fault code prompt easy maintenance intelligent speed adjustable cooling fan low running noise compact wall mounted structure space saving easy installation indoor ip21 protection grade durable metal heat dissipation housing
5 north america market certified design match us canada mexico electrical standards all in one integrated inverter charger mppt controller reduce wiring cost cost effective off grid backup power solution rural cabin villa small office power shortage area renewable energy storage system long service warranty customizable technical parameters and private label service








| Parallel mode | |
| Permitted parallel number | NO |
| AC Mode | |
| Rated input voltage | 120(L1/N,L2/N)/240Vac(L1/L2) |
| Input voltage range | (85Vac~140Vac)±2% |
| Frequency | 50Hz/60Hz (Auto detection) |
| Frequency Range | 47+0.3Hz~55±0.3Hz(50Hz);57+0.3Hz~65±0.3Hz (60Hz) |
| Overload/short circuit protection | Circuit breaker |
| Efficiency | >95% |
| Conversion time (bypass and inverter) | 10ms (typical) |
| AC reverse protection | Yes |
| Maximum bypass phase overload current | 2pole, 40A/40A(L1/L2) |
| Inverter Mode | |
| Output voltage waveform | Pure sine wave |
| Rated output power (VA) | Split phase: 6200/Single phase: 4800 |
| Rated output power (W) | Split phase: 6200/Single phase: 4800 |
| Power factor | 1 |
| Rated output voltage (Vac) | 120Vac (L1/N, L2/N)/240Vac(L1/L2) |
| Output voltage error | ±5% |
| Output frequency range (Hz) | 50Hz±0.3Hz/60Hz±0.3Hz |
| Maximum Efficiency | >92% |
| Overload protection | (105% < load <110%) ±5%: report error and turn off the output after 5 minutes;(110% < load < 125%) ± 5%: report error and turn off the output after 10 seconds;Load >125% ±5%: report error and turn off the output after 5 seconds; |
| Peak power | Split phase: 12000VA/Single phase: 10800VA |
| Loaded motor capability | 4HP |
| Output short circuit protection | Can protect, after continuous short circuit for 0.2 second |
| Bypass circuit breaker specification | 2pole, 63A/63A(L1/L2) |
| Rated battery input voltage | 51.2V (Minimum starting voltage 44V) |
| Battery voltage range | 40.0Vdc~58.6Vdc+0.6Vdc (Under voltage alarm/shutdown voltage/over voltage alarm /over voltage recovery.. settable on LCD screen) |
| Power saving mode self-consumption | Load per phase is null or less than 25W enter power-saving mode |
| AC charging | |
| Battery type | Lead acid or lithium battery |
| Maximum charge current(can be set) | 100A |
| Charge current error | +5Adc |
| Charge voltage range | 40-58.6Vdc |
| Short circuit protection | Circuit breaker and blown fuse |
| Circuit breaker phase specifications | 2pole,40A/40A(L1/L2) |
Online Message